/en/products-services/accessories /en/products-services/products

Force Tensiometer

Tensíío

The new generation tensiometer for liquid and solid surfaces

  • PRODUCT
  • SPECIFICATIONS
  • ACCESSORIES
Compare

Software

Software type ADVANCE
Software languages Chinese (simplified), English, French, German, Japanese, Korean, Portuguese, Russian, Spanish
Software modules Interfacial and surface tension of liquids (optional)

Critical micelle concentration (optional)

Contact angle / surface free energy of solids (optional)

Liquid density (optional)

Solid density (optional)

Special purpose (optional)

Sedimentation - with sensor upgrade / penetration (optional)

Adhesion Analysis (optional)

Remote Control API (optional)

Surface free energy of solids

Results surface free energy
polar & disperse part
acid & base part
H-bond part
Models equation of state
Zisman
Fowkes
Wu
Owens-Wendt-Rabel-Kaelble
extended Fowkes
acid-base theory

Rod

Results surface tension
interfacial tension
critical micelle concentration
Range 1 to 2000 mN/m
Resolution 0.2 mN/m (optional sensor: 0.02 mN/m)

Du Noüy ring

Results surface tension
interfacial tension
critical micelle concentration
Range 1 to 2000 mN/m
Resolution 0.01 mN/m (optional sensor: 0.001 mN/m)
Correction method Harkins-Jordan
Huh-Mason
Zuidema-Waters
linear correction
no correction

Liquid density

Liquid density range 1 to 2200 kg/m³
Resolution 1 kg/m³ (optional sensor: 0.1 kg/m³)

Wilhelmy plate

Results surface tension
interfacial tension
critical micelle concentration
Range 1 to 2000 mN/m
Resolution 0.02 mN/m (optional sensor: 0.002 mN/m)

Solid density

Solid density range 1000 to 20000 kg/m³
Resolution 1 kg/m³ (optional sensor: 0.1 kg/m³)

Sedimentation

Results graph: mass vs. time

Penetration

Results graph: mass vs. time

Washburn

Results contact angle
Resolution 0.01°
Range 0 to 90°
Types advancing

Wilhelmy contact angle

Minimum fiber diameter Fiber analysis not recommended with standard force sensor
Fiber analysis with optional sensor: 7 µm
Results contact angle
Range 0 to 180°
Resolution 0.01°
Types advancing
receding

Instrument dimensions

Footprint 290 mm × 360 mm (W × D)
Height 560 mm
Weight (without accessories) 29 kg

Environment

Operating temperature 15 to 30 °C
Humidity > 30 % without condensation

Interfaces

PC USB 3.0
Auxiliary CAN/CANopen
Thermostat optional
(quick couplings)
Inert gas optional

Housing and peripherals

Built-in bubble level electronic
Built-in and software-controlled ionizer optional
Glass windshield doors yes
Stainless steel measuring compartment yes
Touch display integrated color IPS display
(1024 × 600 pixel, size 7'')

Power supply

Voltage 100 to 240 V
Power consumption 40 W
Frequency 47 to 63 Hz

Temperature measurement

Range -60 to 450 °C
Resolution 0.01 °C
Precision ±0.05 °C
Accuracy ±0.5 °C
Internal sensor sample stage
External sensor optional: sample vessel

Temperature control

Type of temperature control liquid (-10 to 130 °C)
Peltier (-15 to 140 °C)

Camera system (standard)

Connection USB 3.0
Performance 15 fps at 2560 × 1920 px

Optics (standard)

Focus fixed
Zoom 1.4× zoom, fixed
Field of view 6 mm × 4.5 mm
Resolution of optics 2.3 µm

Drive

Resolution 16 nm
Travel speed 0.001 to 800 mm/min
Type of motor brushless DC servo motor

Sample stage

Travel distance 120 mm
Simple platform optional
Temperature control jacket optional: 50 mm, 70 mm
Vessel for inverse CMC optional: cone-shaped vessel
Integrated sample stage yes
Stirrer optional: induction - no permanent magnet

Force measurement

Maximum load 250 g (optional sensor: 210 g)
Resolution 100 µg (optional sensor: 1 µg)
Accuracy ±0.15 mN/m (plate method calibration)
Measurement rate 100 Hz
Adjustment semi-automatic, external 100 g weight required
(optional sensor: automatic with included internal weight)
Locking mechanism automatic

Optical height sensor

Resolution optional: 0.05 µm