K6 accessories

Accessories for our Force Tensiometer – K6 support you in using the instrument and serve to extend its service life.

RI0111 – Measuring probe for the Du Noüy ring method

RI0111 – Measuring probe for the Du Noüy ring method
Ring attached to the Force Tensiometer – K6

The RI0111 ring is our high-precision standard measuring probe for surface and interfacial tension using the Du Noüy ring method. The wire ring made of a platinum-iridium precious metal alloy is ideally wettable; the hardness of the iridium makes the measuring probe especially robust. The ring geometry is only connected to the shaft at two junctures, so that any disturbing influences on wetting are negligible. Safe storage is assured through a high-quality protective box provided.

One RI0111 measuring probe is already contained in the scope of supply of the Force Tensiometer – K6. An RIC0111 version of the ring with a certificate from an independent testing institute is also available.

SV13 – Disposable aluminum sample vessel

SV13 – Disposable aluminum sample vessel

Liquids that cause severe soiling or that cure can be analyzed trouble-free with the aid of the SV13 disposable sample vessel. The vessel has an outer diameter of 50 mm and can hold 20 mL of a sample. The SV13 is available in sets of 100 vessels.

We also offer a matching adapter that positions the sample vessel centrally in the thermostat jacket and ensures optimum temperature control.

TO01 – Tool for adjusting distorted ring measuring probes

TO01 – Tool for adjusting distorted ring measuring probes

The delicate measuring probe for the Du Noüy ring method is easily bent if dropped or accidentally knocked rendering it unsuitable for the measurement. Our special TO01 tool can be used to restore the exact shape of the measuring element.

Alternatively our technical support also provides the re-alignment of deformed rings as a service or carries this out as part of the servicing of your instrument.

SP0110 – Spare force measuring system

SP0110 – Spare force measuring system

In the event the torsion wire of your K6 Force Tensiometer has become overstretched, it can be replaced with a SP0110 pre-calibrated force measuring unit. You can either replace the wire yourself following the instructions in the Force Tensiometer – K6 manual or gladly commission our technical support to replace it for you.

Request more information

Order accessories

For ordering accessories or consumables, please get in contact with your technical consultant or use our contact form to send us a note.